WiFi Heater Install — When to Go Permanent, and When a Plug-In Is Fine
WiFi Heater Install — When to Go Permanent, and When a Plug-In Is Fine
Call Kris on 021 466 666
WiFi-controlled panel heaters, convection heaters and oil-column heaters have taken over the room-heating market. Redwood, Rinnai, Goldair, Devola, Bromic. The question that comes up on nearly every install: does it need to be wall-mounted and permanently wired, or is a plug-in setup good enough?
What the rules say about permanent vs plug-in
Two things drive the decision: clearance distances and the manufacturer's instructions.
Clearance distances are non-negotiable. Every panel and convection heater has minimum distances it has to be kept from curtains, furniture, ceilings, the floor, and combustible materials.
If you can hit those clearances with a plug-in unit, plug-in is fine. If the only viable heater position doesn't have a socket nearby, you've got two choices: add a new permanent socket in the right position, or wire the heater in permanently.
When a permanent install is the right answer
The heater is a fixed feature of the room — wall-mounted, staying in that position for years.
Bathroom or wet-area heaters need permanent wiring with switching outside the wet zone.
Underfloor heating is always permanently wired and switched.
Higher-wattage units (2kw+) are often more reliable on a permanent connection.
You want it on a timer or BMS separate from the heater's own controls.
When plug-in is fine
Smaller units (under ~1500w) that might move between rooms seasonally.
Rental properties where the landlord wants the heater to come with the tenant.
Rooms where wall-mount doesn't suit.
Heaters on castors — explicitly designed to be moved.
There's no shame in plug-in.
What a typical multi-heater install actually looks like
Three heaters across three rooms in one go: two rooms get wall-mounted permanent installs off existing nearby sockets, with a new spur for one of them. The third room gets the heater on castors, plugged into a new properly positioned socket. Whole job typically takes a half-day for a two-person team.
What to ask your sparky before they quote
Will the heater locations meet manufacturer clearance distances?
Where are the existing sockets, and will any of them work?
If a new socket is needed, can it come off an existing circuit or does it need its own?
Is the existing switchboard set up to take a new circuit if needed?
Will the install be tested and certified?
How Cosine handles it